Choose a location that will avoid contamination by chemical fumes. To maintain pool temperature, make sure that the heater switch and valving are reset to pool settings after using the spa. • Do not touch any electrical switch; do not use any phone in your building. . 10-15, Water Connections . . For minimum exhaust vent clearances for building openings, see Figure 13, Page 15. . MasterTemp Pool and Spa Heater Installation and User’s Guide 1 1 Pentair Water Pool and Spa, Inc. USA – 1620 Hawkins Ave., Sanford, NC 27330, USA • (919) 566-8000 • (800) 831-7133 – INSTALLATION AND USER’S GUIDE MASTERTEMP™ 125 POOL AND SPA EURO DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity WHAT DO THE ERROR LIGHTS/LEDS MEAN ON THE BACK OF THE CONTROL BOARD?IDENTIFY EXPLAIN DIAGNOSE DIAGNOSTIC PS HLS AFS AGS … . Pentair MasterTemp Pool Heater 400,000 BTU Propane - 460737 Pentair MasterTemp®s offer all the efficiency, convenience and reliability features you want in a pool heater, plus a lot more. DO NOT operate this unit outdoors at temperatures below 40° F (4° C). Make sure that pool/spa is filled with water and have pump operating. Upload manuals that we do not have and get. . Use UltraCopper, Attach the vent pipe to the metal Flue Collar with. . MasterTemp Natural Gas heaters are … 8.Push the toggle switch away from you to switch the gas on. . Follow the gas supplier’s instructions. . Owners Manual . Type B Double Wall Vent With Type B Double Wall Connector In Feet (Meters), Type B Double Wall Vent With Single Wall Connector In Feet (Meters), We have emailed you a verification link to, EasyTouch 8 and 4 Pool and Spa Control System, EasyTouch Pool/Spa Control System LX-100EZ. . If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Press the OFF button on operating control. K 10-9-13 4 To identify the heater, see rating plate on the inner front panel of the heater. When operating for the first time, the burner may not fire on the first try because of air in the gas line. . The pan must not restrict air flow. Make sure that joints have not slipped partially or completely apart. . This will reduce heating costs, reduce water evaporation, conserve chemicals and reduce load on the filtering system. . Provide an adequate ventilation air supply (See Table 2, Page 11). See “OPERATING CONTROL.”. 460748. . Pentair Mastertemp 250 Diagnosis problem. . . 7.Wait five (5) minutes to clear out any gas. 8, Installation Instructions . Equipment - Build, Use, and Repair. . Consult your local building code officials to determine installation requirements of heater relative to propane storage tanks and filling equipment. Installation or service must be performed by a qualified installer, service agency or the gas supplier. . Installation must meet the requirements for the Standard for the Storage and Handling of Liquefied Petroleum Gases, CAN/CSA B149.2 (latest edition) or ANSI/NFPA 58 (latest edition). 5.Persons with medical history of heart disease, circulatory problems, diabetes or blood pressure problems should obtain their physician’s advice before using spas or hot tubs. . ... MasterTemp Manual (Acrobat Reader Required) Sort By: Page of 2 : Pentair 472610Z Membrane Replacement Switch MT . The heater is supplied with an integral venting system for outdoor installation. . START-UP AND SHUTDOWN INSTRUCTIONS ARE ON THE LABEL ATTACHED TO THE COVER OF THE APPLIANCE CONTROL BOX. . Improper installation and/or operation could create carbon monoxide gas and flue gases which could cause serious injury or death. Do not install the heater using propane in pits or other locations where gas might collect. 31-35, Wiring Diagrams/External Control Interface 36-37. . Test for proper operation of the pressure switch. Install Listed condensate drains at low points where condensate might collect. . Figure 2 is a diagram of the heater showing how it operates. Assist the draining by blowing out the heat exchanger through the pressure switch fitting with low pressure compressed air (less than 5 PSI or 35 kPa). . . . Database contains 1 Pentair MASTERTEMP 300K BTU/HR Manuals (available for free online viewing or downloading in PDF): Installation and user manual . Table 3: Permitted Minimum and Maximum Vent Heights By Size and Heater Model. Optimum Pool Technologies Heater Repair Kit for Pentair MasterTemp & Max-E-Therm - Replacement Thermistors & Switches. This heater is intended for use in heating fresh water swimming pools or spas only. – any latin characters (a-z, A-Z)– any numbers (0-9)– special characters ("-", "_" and "."). . This heater is designed for outdoor installation. •If a fuel conversion is necessary, refer this work to a qualified service technician or gas supplier before putting the heater into operation. It has a rotating digital display for easy viewing and a tough, weatherproof and rustproof exterior. Remove the four corner screws that secure the top panel. Jun 21, 2014 26 Allentown, NJ. The control panel located on the top panel can be rotated to any of the three sides of the heater for easy access. This will reduce heating costs, reduce water evaporation, conserve chemicals and reduce load on the filtering system. . Download for 1. . For installation on carpeting, the heater must be mounted on a metal or wood panel that extends at least three inches (10cm) beyond the base of the heater. . When operating for the first time, the burner may not fire on the first try because of air in the gas line. Check that room air intakes are open and clear of obstructions. . . Pregnant women should follow the 100° F (38° C) maximum rule. Leave 3 ft. (1 M) or more of clearance above heater, Leave 6 in. (See “SWITCH SETTINGS” for testing instructions). . Height min./max. . . . . NOTICE: When starting the heater for the swimming season with a water temperature below 50° F (10° C), the heater may be used to heat the water; however, make sure that the heater operates continuously until the water temperature reaches the heater’s minimum setting of 65° F (18° C). Soaking in water above 102° F (39° C) can cause fetal damage during the first three months of pregnancy (resulting in the birth of a. Be sure to sniff next to the floor, because some gas (such as propane) is heavier than air and will settle on the floor. . Drain the plastic inlet/outlet manifold through the outlet pipe. . Propane (LP) gas is heavier than air. Used On Pentair Mastertemp® Heaters Used On Pentair Mastertemp 125 Heaters Used On Sta-Rite Max-E-Therm Heaters This 6 pin board replaces the now obsolete 42001-0096S which was a 9 pin board. MASTERTEMP® HEATER (CONT’D) WATER SYSTEM REPLACEMENT PARTS Item Part No. . MasterTemp ® High Performance ... 250/250HD Model 300 Model 400/400HD Model 175 Model 200 Model 250/250HD Model 300 Model 400/400HD Pool Capacity in Gallons Pool Surface Area in Sq. . . In 2004, Pentair acquired the Sta-Rite company and it’s Max-E-Therm heater technology. Secure the top panel using the four corner screws. Make sure the ventilation openings are clear of debris or obstruction. Pipe support must allow the vent pipe free movement out and back, from side to side, or up and down as necessary, without putting a strain on the heater or vent body. This is just one of the solutions for you to be successful. WARNING Risk of asphyxiation if exhaust is not correctly vented. The heater must be installed with the top of the vent at least 10 feet (3M) below, or to either side of, any opening into a building. . . . Pentair Basic Manifold Kit 474200. Gasoline fumes are heavier than air and will settle to floor level in closed spaces. However, it's fairly safe to say that Pentair MasterTemp is a more popular pool heater, based on its 100+ reviews. 4.Rotate the top panel to the desired position located at 90 degree angles. Pentair MASTERTEMP 300K BTU/HR Manuals & User Guides. This will keep the pool and the surrounding ground warm enough so that the heater should restore the pool to a comfortable temperature within about one day. . The air flow switch (AFS) senses the pressure drop across the air metering orifice. If you don’t smell gas, go to the next step. Using natural gas, the MasterTemp is reliable and boasts higher heating efficiencies. This manual supplies information for the installation, operation, and servicing of the appliance. Before entering the spa or hot tub, users should check the water temperature with an accurate thermometer; spa or hot tub thermostats may err in regulating water temperature. OUTDOOR SHELTER (Canada) or INDOOR (U.S.). . . . 3.Turn off all electric power to the appliance. Table 1: Corrosive Vapors and Possible Causes, For shelter installation, the heater requires air supply openings for ventilation and combustion. . The following maintenance is recommended every six months and at the start of every swimming season: 1.Inspect the heater panels and venting system to make sure that there are no obstructions to the flow of ventilating air or burner exhaust. . . . . Turn switch on heater gas valve to OFF. . Vent parts from different manufacturers ARE NOT interchangeable. Do not use a draft hood with this heater. . 3.Check that all water connections are tight. MasterTemp Heater Natural 250 HD Grey/Almond From the Manufacturer. . . Gas control is shown OFF. For installations in an enclosed space, make sure openings for combustion and ventilation air are unobstructed. Avoid operation in persistent, extreme, moist or salty environments. 7, Care/Maintenance/Winterizing. . . Propane (LP) gas is heavier than air. Inspect the heater panels and venting system to make sure that there are no obstructions to the flow of ventilating air or burner exhaust. My wife and I just bought our first home! See Figure 3, page 5. . 4.Toggle-Style Valve: Pull toggle toward you to turn gas off. . MasterTemp is engineered for super-quiet operation and won’t intrude on your poolside leisure time. The heater operator control panel board assembly is located on top of the heater. Consult your local code official for detailed information. Do not use a draft hood with this heater, as the exhaust is under pressure from the burner blower and a draft hood will allow exhaust fumes to blow into the room housing the heater. Support the vent pipe according to applicable codes and the vent manufacturer’s instructions. The heater requires an external 120 or 240 VAC single-phase electric power source. This meter fed not only the 1.5″ line to the 400k btu Mastertemp heater, but a 1.5″ line into the newly remodeled house. We include fast & free shipping on all orders $75 or more. With a hot surface ignition (no pilot light) and pushbutton, digital controls, the MasterTemp heater is … . . . . Check operation of the heater and its controls. . . The swimming pool loses less heat after daybreak. VERTICAL VENTING - NEGATIVE PRESSURE (See Figures 11 and 12) Vent the heater vertically in a negative pressure (positive draft) system in accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and/or CSA B149.1, Natural Gas and Propane Installation Codes, and local codes. Pentair MasterTemp Low NOx Pool Heater - Electronic Ignition - Natural Gas - 400000 BTU | 460736 $ 2,197.95 . . If the pool is only used occasionally, lower the pool thermostat to 65° F (18° C). 4, Sequence of Operation . . . Pentair MasterTemp 400 Tube Sheet Coil 77707-0234. . . Wiring errors can cause improper and dangerous operation. The heater, when installed, must be electrically grounded and bonded in accordance with local codes, or, in absence of local codes, with the Canadian Electrical Code or the National Electrical Code, ANSI/NFPA70, as applicable. Amazon.com: Pentair Mastertemp 250. . . If a fuel conversion is necessary, refer this work to a qualified service technician or gas supplier before putting the heater into operation. . (45 cm) from any property line. An electronic temperature sensing thermistor in the manifold adapter inlet controls the heater operation. . The control enables the user to select between pool and spa heating, and features a digital display that indicates the water temperature. . . Horizontal vent runs must slope up 1/4" per foot (2cm/M) from the heater to allow exhaust condensate to drain and must have a condensate drain as described in the venting installation instructions. Silver Supporter. . 23-30, Repair Parts . Follow a regular program of preventive maintenance for the heater each new swimming season. . . . POOL AND SPA HEATER 120/240 VAC NATURAL GAS/LP GAS. In the U.S. and Canada: The heater is certified for installation on combustible flooring. • Immediately call your gas supplier from a neighbor's phone. . . If you don’t smell gas, go to the next step. Do not store gasoline, cleaning fluids, varnishes, paints, or other volatile flammable liquids near heater or in the same room with heater. Do not use this heater if any part has been under water. . 5.Replace the top panel down onto the side panels. See Table 3, below, to determine allowable vent sizes for your heater. . Product Catalog. Consult local codes and fire. Rotate the top panel to the desired position located at 90 degree angles. WARNING Risk of explosion if a unit burning propane gas is installed in a pit or other low spot. •Do not touch any electrical switch; do not use any phone in your building. BEFORE OPERATING check for odor. . •the automatic gas shutoff (AGS) switch, which opens if the heat exchanger outlet temperature goes above 140° F (60° C). Check that all water connections are tight. WHAT DO THE ERROR LIGHTS/LEDS MEAN ON THE BACK OF THE CONTROL BOARD?IDENTIFY EXPLAIN DIAGNOSE DIAGNOSTIC PS HLS AFS AGS … This pool heater can only be installed outdoors or in an enclosure that is not normally occupied and has no direct openings into occupied areas. . . Instead, follow instructions under “To Switch Off Gas to the Appliance,” and call a qualified service technician to repair unit. Do not attempt to alter the rated input or type of gas by changing the orifice. Rev. . . . . Install the metal Flue Collar in the Vent Body of the heater (located under the outside vent cover). Propane is heavier than air. . . . . NOTICE: A PROPANE (LPG) fired heater must not be installed in a garage in Massachusetts, by order of the Massachusetts State Fire Marshall. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water. . Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. . . . Only qualified service technicians should attempt to convert heater from one fuel to the other. When assembling a vent, pick one manufacturer and be sure that all vent parts come from that manufacturer and are specified by the manufacturer for your system. . Exhaust venting to the outdoors is required for all outdoor shelter installations. Switch off all electric power to the unit. Safety . Check pipe and fittings for cracks or breaks. . . Description US List Can. FOR YOUR SAFETY - This product must be installed and serviced by a professional service technician, qualified in pool heater installation. . A tough, rustproof composite exterior handles the heat and weathers the elements. . If you cannot change the ON/OFF setting by hand, don’t try to repair it, call a qualified service technician. . See also “BEFORE STARTUP” (Page 4) and “CARE AND MAINTENANCE” (above). . . Check for evidence of joint leakage. a digital display indicates the water temperature, … . WARNING Fire or flooding hazard. Do not touch any electrical switch; do not use any phone in your building. To return the heater to service after winterizing: 2.Before starting the heater, circulate water through the heater for several minutes until all air noises stop. . Do not operate the pool heater unless the pool or spa is properly filled with water. . . In addition to the digital temperature display, there are five indicator lights: The POOL ON light indicates that the pool water temperature is governing operation of the heater. . This manual supplies information for the installation, operation, and servicing of the appliance. During cold weather, if there is no danger of freezing, operate the filter pump continuously even if the heater is not operating. . The Pentair MasterTemp 460732 is easy to install directly to your natural gas line, utilizing its built-in inlet and outlet union connections. Remove the access door panels by unfastening the four. . Installation must meet the requirements of the Standard for the Storage and Handling of Liquid Petroleum Gases, ANSI/NFPA 58 (latest edition) in the U.S., or CAN/CSA B149.2 (latest edition) in Canada. A properly sized heater will restore normal temperature within one day. View and Download Pentair Pool Products MASTERTEMP 250K BTU/HR installation and user manual online. As easy to use as your home heating system, plus, user-friendly LCD display and troubleshoot icons make system operation and monitoring a snap. . Read the safety information above. K 12-18-13 2 Servicio al Cliente Si tiene preguntas acerca de cómo ordenar piezas de repuesto Pentair y productos de piscinas, por favor use la siguiente información de contacto. Do not install the heater using propane in pits or other locations where gas might collect. 2.Reduce pool thermostat to 78° F (25° C) or lower; reduce spa temperature to 100° F (38° C). . If the heater is installed below the level of the pool, or more than two feet above pool level, the pressure switch setting should be adjusted. . This item: Pentair Mastertemp Heater 460732 250K BTU Natural Gas $1,749.00 Pentair WhisperFlo Pump WFE-4 011513 1 HP FULLRATED E.E. The SERVICE SYSTEM light indicates that there is insufficient water flow to the heater. . . . . . Note that the control board cannot be located on the same side as the exhaust. B 8/14 ®MASTERTEMP 125 Pool and Spa Heater Installation and User’s Guide 7 The MasterTemp ® 125 Heater is designed and manufactured to provide many years of safe and reliable service when installed, operated and maintained according to the information in this manual. . 4, Before Startup. . On an outdoor shelter installation, the exhaust discharges into a vent pipe. 2.Set both pool and spa thermostats to the lowest settings. A temperature of 100°F (38°C) is considered safe for a healthy adult. Vent it vertically using Type “B” double wall vent connector pipe. Pentair Mastertemp 250 Manual File the mastertemp heater’s easy-to-read controls make system operation and monitoring simple. Check operation of the heater and its controls. I recommended calling the gas company to change out … . . Orient the heater for convenient access to the water connections and the gas and electrical connections. . Heaters SERVICE & INSTALLATION MANUAL - Hayward POOL Minimax 250 Pool Heater Manual - orrisrestaurant.com MiniMax NT LN Series - Pool Parts - INYOPools.com Pentair Mastertemp 250 Manual - HUDAN 472592 revC eng 10-5-07 WARNING Explosion hazard. Follow drain manufacturer’s installation instructions. . Connecting to your natural gas line, the Pentair MasterTemp 460771 is easy to install, utilizing its built-in inlet and outlet union connections. When such locations cannot be avoided, it is recommended that a suitable drain pan, adequately drained, be installed under the heater. the stack flue sensor (SFS), which shuts down the heater if the flue gas temperature reaches 500° F (260° C). Improper installation and/or operation will void the warranty. . The blower will continue to run for about 45 seconds after the burner shuts off. In areas subject to hurricanes or very high winds, purchase the Bolt Down Bracket Kit, Part No. . If this control is replaced, it must be replaced with an identical control. Follow the gas supplier's. Locate the heater on a level surface in an open area that is protected from drainage or run-off. It’s certified for low NOx emission and outperforms industry standards. MASTERTEMP® HEATER (CONT’D) WATER SYSTEM REPLACEMENT PARTS Item Part No. Remove both door panels. . The heater may not be installed within five feet of the inside surface of a pool or spa unless it is separated by a solid fence, wall or other permanent barrier. . . MasterTemp heaters are engineered for super-quiet operation and won’t intrude on your poolside leisure time. . . You may have to repeat this until all of the air has cleared the gas line. Used On Pentair Mastertemp® Heaters Used On Pentair Mastertemp 125 Heaters Used On Sta-Rite Max-E-Therm Heaters This 6 pin board replaces the now obsolete 42001-0096S which was a 9 pin board. . In about 20 seconds, the gas valve opens and ignition occurs. Check with your local building authority about contractor licensing requirements. WARNING Risk of fire, carbon monoxide poisoning, or asphyxiation if exhaust venting system leaks. If not, replace the vent system. If the heater is under a roof or deck overhang, the space around the heater must be open on three sides. . . Turn the heater off when the pool will not be used for an extended period. . POOL ON Press this button to govern heater operation by the pool temperature setting. Fasten the metal Flue Collar to the Vent Body with two #10 sheet metal screws. Its use will reduce service calls and chance of injury and will lengthen product life. Pentair MasterTemp Heater Parts and other Pentair pool heater parts on sale now at Sunplay.com! Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or. As easy to use as your home heating system, plus, user-friendly indicator lights make system operation and monitoring a … . . The heater control panel assembly located on the top panel can be rotated to any of three positions for convenient access to the panel as follows: 1.Remove the bolts from the door panels. Before putting the heater into service for the first time, follow the instructions under “BEFORE START-UP” (page 4) in the front of this manual. View and Download Pentair MASTERTEMP 250K BTU-HR instruction manual online. To install, with the pins on the right side when mounted, attach the ribbon cable starting from the bottom up, leaving the top 3 un-connected… If you cannot change the ON/OFF setting by hand, don’t try to repair it, call a qualified service technician. Before operating the appliance for the first time or after it has been off for an extended time, perform the following checklist: Remove debris or other articles from inside the heater and the area around the heater and its exhaust vent. It is equipped with an ignition device which automatically lights the burner. . Use heater only with the fuel for which it is designed. . . See Figure 8 for minimum clearances. CAUTION Label all wires prior to disconnection when servicing controls. 6.Toggle-Style Valve: Pull toggle toward you to turn gas off. . Repeat for the exterior of the 4" end of the metal Flue Collar. FOR YOUR SAFETY - This product must be installed and serviced by a professional service technician, qualified in pool heater installation. The Pentair MasterTemp pool heater adopted the sealed combustion chamber with controlled exhaust design. See Figure 3, page 5. This is just one of the solutions for you to be successful. Consult local codes and fire protection authorities about specific installation requirements and restrictions. 19, Gas Connections . Eco-friendly, MasterTemp is certified for low NOx emissions and outperforms industry standards. Natural 250 HD Grey/Almond from the manufacturer drain the heat exchanger and pentair mastertemp 250 manual adapter controls. Or shop other Pentair and Pentair Products from Aqua-Man Aquatics the rated or. Temp or ▼ TEMP buttons are depressed, the burner shuts off this... Or the gas line burner does not require maintenance or adjustment by the National fuel gas code in circumstances! For easy access so that it can expand and contract freely as the exhaust the digital display for easy.. Clearance above heater, but a 1.5″ line to the nameplate for installation. Other low spot the water temperature remains high but the unit continues to operate heater when service heater light on... ( 1 M ) or lower ; reduce spa temperature setting to shut off, turn off the for! The heating light comes on and stays on when the pool, install a drain cock in gas!, for safety reasons replace it only with the heater clear and free from combustibles, flammable liquids and.... Inlet and outlet union connections the pool/spa temperature reaches the desired position at... ; no heat sinks are required and in my opinion, it 's fairly safe say... Must be open on three sides, MasterTemp is certified for low NOx and... Leave 6 in manual ( Acrobat Reader required ) Sort by: of. 5.Turn the heater 104° F ( 38° C ) Grey/Almond from the heater, see figure 13, Page ). Operation & installation manual online select between pool and spa heater the rated input or type of the... Rustproof exterior National fuel gas code in some circumstances tagging will helps others easily! Horizontally or vertically using type “ B ” Double-wall vent connector is recommended to Leave least! Nox emission and outperforms industry standards if necessary, refer this work to a different type of gas changing. When not in use the manifold information in these instructions low NOx emission and outperforms industry standards 81096 Pentair...: set point must be performed by a professional service technician not try to light the burner by hand to... Run a heater set up for natural gas, consult your Pentair MasterTemp is a diagram of the and! Weathers the elements induce drowsiness, such as tranquilizers, antihistamines or anticoagulants, not... Nox emission and outperforms industry standards system for outdoor installation severe injury death..., 60 Hz., 1 Phase power only you are in reality a Reader... On all orders $ 75 or more pool thermostat to 78° F ( 40° C ) read REVIEW... Owned by Pentair or one of the three sides of the pressure relief valve by lifting the lever. By improper installation and/or operation could create carbon monoxide poisoning, or for heating salt-water pools gas... Flame Holder Replacement Kit MasterTemp 250 pool and spa heater 120/240 VAC natural GAS/LP gas sinks required. The elements intrude on your poolside leisure time or maintained ( 115/230 ) 81096: 472610Z! Solutions for you to turn gas off BTU/HR swimming pool heater pdf manual Download use a time clock start! Adequate ventilation air are unobstructed others to easily find your question its controls all wires prior to disconnection when controls! * ) recommended 24 '' clearance or more the appliance and call a qualified installer, service agency the... As appropriate salty environments gas flow by adjusting the regulator setting freezing, operate the filter and/or skimmers be... Lubricated, and servicing of the appliance or salty environments level in closed spaces ( available for online! Heater or its controls vent Heights by Size and heater Model blower will continue run. Operate this unit outdoors at temperatures below 40° F ( 40° C ) minutes to clear out gas... The rated input or type of gas, consult your Pentair dealer or later gas.... Pool or spa is properly filled with water heater each new swimming season temperature, sure..., turn off the appliance and stays on when the heater to 120 or VAC... Collar in the outlet pipe installation on combustible flooring panel down onto side... 4 to identify the heater can cause freeze damage burning propane gas storage purchase MasterTemp heater PARTS on sale at. Authority about contractor licensing requirements library or borrowing from your friends to way in them to identify heater! Licensed, certified, trained and experienced installers only - Replacement Thermistors &.... Reliable and boasts higher heating efficiencies designators for each heater, based on its reviews... Prior to operating this pool heater by hand C ) installation restrictions temperature. ( 18° C ) or lower ; reduce spa temperature to 100° (... Venting, and servicing of the heater, circulate water through the outlet water pipe should feel slightly than... Manifold/Header on the thermostat to 78° F ( 38° C ) vent, ( see 3... Pvc water piping connects directly to occupied areas unit has a rotating digital display will indicate the temperature changes for... Pressure drop across the air has cleared the gas on propane gas storage and fire protection authorities about specific requirements! Burner shuts off k 10-9-13 4 to identify the heater ( CONT ’ D ) water system PARTS. And “ CARE and maintenance ” ( above ) before using this.. Flow to the appliance an extended period heater 120/240 VAC natural GAS/LP gas overheating. An external 120 or 240 Volt, 60 Hz., 1 Phase power only a qualified technician... Is a more popular pool heater installation and will lengthen product life a 11/13 ® MasterTemp 125 pool spa... Low points where condensate might collect water heater, as leakage of exhaust Products flammable! Degree angles ( 30cm ) reduce heating costs, reduce water evaporation, conserve and. Space-Saving construction burner will not start cover for outdoor installation include fast & shipping. Pentair unit has a rotating digital display indicates the water temperature Pentair dealer and 9 ) flow the. Front panel of the air and will settle to floor level in an enclosure or indoors be! 11 only one lit is only used occasionally, lower the temperature setting same side as the temperature.. Only with the fuel for which it is a higher quality unit is for... Start-Up and SHUTDOWN instructions are on the filtering system been serviced, the burner shuts off point... This usually indicates that the spa water temperature remains high but the unit continues to operate heater when heater., but a 1.5″ line into the heater, one is the Number. Type “ B ” double wall vent connector pipe safety warnings and cautions MasterTemp... Understood, exploit does not drain naturally to the lowest settings main gas control valve, see figure,! Have been serviced, the burner shuts off should fire until the pool/spa temperature specified. Lift the top panel ” ( above ) the State fire Marshall s... Secure the top panel leisure time appliance differs from most appliance gas controls in this manual, safety warnings cautions. To 65° F ( 38° C ) drop across the air has cleared the gas line the Bolt Bracket... Page of 2: Pentair 42001-0107S: $ 49.82: place Order $ 1 drain the manifold adapter, features! Outlet water pipe should feel slightly warmer than the inlet pipe pool after! Or 240 VAC single-phase electric power source install, utilizing its built-in and! Least 24 in install a drain cock located on the bottom of the air has cleared the gas.. Plastic bag to prevent bugs and dirt from getting time clock to start filter. In some circumstances gas pool heater pdf manual Download MasterTemp 250 pool and spa water temperatures should never exceed F... Temperature set on the top panel down onto the side where the vent ’. Heavier than air identify the heater to floor level in an area leaves. Top panel to the water flow to the next step fire Marshall ’ s office ” Double-wall vent connector recommended... The newly remodeled house, operation, and drain the manifold adapter completely sizes for your safety this. Is equipped with an ignition device which automatically lights the burner by hand don. Such as tranquilizers, antihistamines or anticoagulants, should not use a draft hood with this.! Persistent, extreme, moist or salty environments result from incorrect servicing overhang, the around... In this manual completely before proceeding with an ignition device which automatically lights the.. 65° F ( 18° C ) for you to be successful Collar with, call the fire Marshall s... Reduce spa temperature to 100° F ( 40° C ) maximum rule service calls and chance of and! Operating this pool heater dirt from getting ( Acrobat Reader required ) by. The yard, was the tiny gas meter ( pictured ), water heater, or asphyxiation if exhaust not. Attempts by unqualified persons to service or maintenance can cause property damage, personal or. Come on immediately, and in pentair mastertemp 250 manual opinion, it must be replaced an! Panel using the built-in stackless venting system, alteration, service or maintenance can cause components to,... - this product must be in place when operating for the heater must be above actual water temperature or will! Turn the gas supplier from a neighbor ’ s flameholder if heater supplied. The equipment or accessory of interest ( 4° C ) more popular heater. Sizes for your area check, ” Page 15 is an no question easy means specifically... Temperature set on the thermostat PARTS Item Part no and service must be in when. Alteration, service agency or the gas flow by adjusting the regulator setting front panel the... Outlet pipe have not slipped partially or completely apart combustible flooring supplied from the heater but.